Gamma-ray attenuation parameters of HDPE filled with different nano-size and Bulk WO3
Abstract
High-density polyethylene (HDPE) was obtained through a compression molding technique, and incorporated with different filler weight fractions (0, 10, 15, 25, and 35%) of bulk WO3, and two different WO3 nanoparticle sizes (45 nm and 24 nm). The radiation attenuation ability of the new category of polymer composite HDPE/WO3 was evaluated using gamma-ray energies ranging from 59.53 up to 1332.5keV of four radioactive sources 241Am, 133Ba, 137Cs, and 60Co. The mass attenuation coefficients
, the total molecular cross-section
, the effective atomic cross-section
, the total electronic cross-section
, the effective atomic number
, electron density
, the half value layer (HVL), the tenth value layer (TVL), and the relaxation length were investigated. The obtained results of the gamma-ray attenuation parameters exhibited an outstanding influence of the size and weight fraction of WO3 filler on the gamma-ray shielding ability of the HDPE composite. A significant improvement was detected at low gamma-ray energies. The HVL of the synthesized HDPE composites is compared with that of pure lead as a conventional shielding material. HDPE composite filled with the smaller size of WO3 nanoparticle shows good improvement in the attenuation parameters, which suggests promising applications in radiation protection and gamma-ray shielding.
Journal/Conference Information
Applied Radiation and Isotopes,DOI: https://doi.org/10.1016/j.apradiso.2023.110790, Volume: 197, Issue: 1, Pages Range: 1-9,